Abstract

This article models and characterizes the input impedance of a single-phase totem-pole power factor correction (PFC) converter in a virtual synchronous reference (d-q) frame. Due to the dc voltage controller, its d-d channel impedance behaves like a negative resistor, and the cascaded dc–dc converter load reduces its gain and phase at low frequency. Both are detrimental to system stability. The proposed impedance model can be employed to analyze instability issues. As examples, the low-frequency stability of a single-phase and a three-phase four-wire system is analyzed using the model. It is found that the single-phase system will confront the issue of settling to an operating point before any small-signal instability occurs. Whereas in a four-wire system, high neutral line inductance or high dc voltage control bandwidth could lead to small-signal instability. The impedance modeling results are validated by experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.