Harmonics are a very important issue in the design and operation of medium-voltage inverter drives, due to restrictions imposed by regulations. This paper studies the harmonics generated by a three-phase multicell cascade inverter, with single-phase pulsewidth modulation rectifiers at the input side of each cell; thus, the entire topology is able to regenerate power to the net. This paper identifies accurately the harmonic generation process in the dc-link voltage, the input current of each cell, and, therefore, at the input side of the inverter. Moreover, this paper proposes a method to reduce and, in some cases, eliminate the input current harmonics, reaching a very high input power factor for any operation condition. Simulation and experimental results are provided to validate the theoretical analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.