Abstract
Harmonics are a very important issue in the design and operation of medium-voltage inverter drives, due to restrictions imposed by regulations. This paper studies the harmonics generated by a three-phase multicell cascade inverter, with single-phase pulsewidth modulation rectifiers at the input side of each cell; thus, the entire topology is able to regenerate power to the net. This paper identifies accurately the harmonic generation process in the dc-link voltage, the input current of each cell, and, therefore, at the input side of the inverter. Moreover, this paper proposes a method to reduce and, in some cases, eliminate the input current harmonics, reaching a very high input power factor for any operation condition. Simulation and experimental results are provided to validate the theoretical analysis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.