Abstract

Five full-scale timber floors were tested in order to analyze the in-plane behaviour of these structural systems. The main objective was to assess the effectiveness of the in-plane strengthening using cross laminated timber (CLT). For that, one unstrengthened specimen (original), one specimen strengthened with a second wood board, two specimens strengthened with 3 CLT panels and one specimen strengthened with 2 CLT panels were tested. Moreover, because of its importance in the composite behaviour, the first phase of the experimental program was composed by push-out tests on specimens representing the shear connection between the timber beams and the CLT panels. This paper describes the tests performed and the numerical modelling aimed to evaluate the composite behaviour of the strengthened timber floors.Keywordsexperimental evaluationin-plane stiffnessstrengtheningconnection

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.