The objective of this study was to develop a better understanding of the seismic behavior of nonstructural partition walls and to provide damping methods in order to improve such behavior. This paper summarizes the findings of the study, where nine full scale wall specimens were divided into three groups of different damping systems and tested under cyclic loading conditions. The wall specimens were made of light gauge steel studs and sheathed on both sides with gypsum board (GB). Three specimens were constructed with single rubber grommet dampers, three specimens with double dampers and three wall specimens were constructed without damping system in order to have a basis for comparison. Test results included cyclic hysteresis and envelop curves of load–displacement relationships, damages and failure modes as described by photographs taken during and after testing, and ductility factor for each damping system. Based on the cyclic envelope curves, peak load capacities and their corresponding drifts were determined. Further, comparison of the peak points envelopes for none, single, and double damping specimens provided vital understanding of the relative drift capacities of the walls in addition to the ductility factor which is a measure of ductility. Damages and failure modes were noted through visual inspection and photographs. The study concluded with recommendations for further studies.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.