Abstract

Two kinds of innovative measurement method of EDLC's equivalent circuit constants are presented in this paper, “simplified energy method” and “charge-energy method”. The measurement principle of the former method is the same as that of the previously reported “energy method”, but the procedure is much more simplified by employing an analytical approach. In addition to energy, electric charge is incorporated into the latter one to estimate an internal resistance analytically using a simultaneous equation regarding energy and charge. Through the verification with the constant current charge-discharge experiments, we confirmed that both of the proposed measurement methods are concise, highly accurate and reliable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.