Abstract

For accurate and reliable analysis of microplastics (MPs) in wastewater (WW), it is imperative to comprehend the significance of pre-treating WW before analysis. The suspended solids (SS) in the matrix tend to adhere to the MPs during filtration, which interferes with the detection of the MPs. In this regard, the present study aims to develop and optimize a pretreatment method to improve the extraction efficiency of MPs from WW by reducing the SS. A combination of the Fenton reaction and ultrasonication, ferro-sonication (Fe-UlS), was proposed to digest and eliminate the SS from WW. This hybrid pretreatment, Fe-UlS, was optimized for ultrasonication amplitude, treatment time, and hydrogen peroxide dose using response surface methodology (RSM) with a Box-Behnken design, achieving a desirability of 0.984. The optimum conditions for the Fe-UlS, such as the (1:1) Fenton reagent ratio (0.05 M FeSO4: 30 % H2O2), ultrasonication amplitude (31 %), and total process time (30 min) were found to be statistically significant (p < 0.05). The developed method was then employed for the extraction of spiked polyethylene (PE), polypropylene (PP) and polyethylene terephthalate (PET) MPs in real WW and found efficient in removing 83 % of the TSS present in the primary influent were in 30 min at a temperature of 45 °C. Also, the method did not affect the physio-chemical characteristics of the MPs; however, the thermal analysis of PE and PP MPs showed a statistically significant decrease in the melting temperature, as proven by paired t-test analysis. Further, a non-targeted liquid chromatography-mass spectrometry (LC-MS) analysis proved that Fe-UlS is a stable process, as it did not cause any leaching of MPs under the optimum pretreatment conditions. Finally, Laser Direct-Infrared Imaging (LD-IR) analysis was conducted to validate the developed Fe-UlS pretreatment approach for MP analysis in real WW. About 3434 MPs were detected in 100 mL of WW primary influent, within the size range of 9 to 500 μm. This hybrid pretreatment approach not only streamlines WW sample processing but also reduces the required concentration of Fenton reagent and processing time, yielding accurate and reliable results for monitoring MPs in WW.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.