Abstract

This paper focuses on the in-mold monitoring of temperature and cavity pressure. The melt contact temperature and the cavity pressure along the flow path were directly measured using two pressure sensors and two temperature sensors fitted into the cavity of a spiral mold. Three melt temperatures and dies of different heights (1.0, 1.5 and 2 mm) were used to achieve a wide range of practically relevant shear rates. In order to analyze the extent to which the numerical simulation can predict the behavior of the molten polymer during the injection molding process, molding experiments were simulated using the Moldflow software and the simulation results were compared with the experimental data under the same injection molding conditions.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call