Abstract
In order to resolve the starting problem for position sensorless interior permanent magnet synchronous motor, an improved initial rotor position estimation method based on square-wave signal injection is presented in this paper. Instead of the conventional sinusoidal voltage injection, square-wave voltage signals are injected into stator windings to obtain magnet pole position. On the basis of saturation and saliency principle, the voltage pulse injection method was adopted to identify the magnet polarity. Detecting the magnet pole position by using the square-wave voltage injection, the error signal can be calculated without low-pass filters and time delays. The proposed method is verified via a 1.5 kW interior permanent magnet synchronous motor drive platform.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.