Abstract

The performance of the initial rotor position detection of Permanent Magnet Synchronous Machines (PMSMs) at standstill depends much on the position observer. In this paper, the Extended State Observer (ESO) is compared with the traditional Proportional Integration (PI) observer adopting the rotating high frequency voltage injection algorithm, and the observer parameter design method is derived based on the bandwidth analysis of the close-loop transfer function. Experiments are carried out on a 3 kW PMSM prototype for verifications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.