Abstract

The purpose of this study was to introduce a new commercial electron FLASH system that has the potential to become widely available for FLASH researchers globally. In this study, we first present the initial acceptance and commissioning tests for the FLASH system, and second, we highlight preliminary FLASH effect results from our cell studies. A linear accelerator was converted into a commercial research platform with the FLASH Research Extension, enabling the generation of a powerful 16 MeV electron FLASH beam. The dosimetric and stability tests were conducted using various dosimeters (i.e., radiochromic film, optically stimulated luminescent dosimeters (OSLDs), and a plane-parallel ionization chamber). To evaluate the FLASH effect, normal and cancer cell lines were FLASH irradiated using different pulse repetition frequencies (PRF) of 18 pulses/s and 180 pulses/s. The electron FLASH mode was able to generate over 1 Gy per pulse at the isocenter and a dose rate of up to 690 Gy/s near the accessory mount of the Linac gantry head. The charge collected by the plane-parallel ionization chamber at the highest PRF (i.e., 180 pulses/s) showed a linear relationship with the delivered number of pulses (i.e., 1 to 99 pulses) with a coefficient of determination (R2) of 0.9996. The absorbed dose measured using radiochromic film and OSLDs agreed within 3%, on average, and followed an inverse square law as the source-to-axis distance (SAD) varied for which the R2 values were 0.9972 and 0.9955 for radiochromic film and OSLDs, respectively. The profile of the FLASH beam was symmetrical but was not as flat as the conventional 16 MeV electron beam due to the use of a thinner custom scattering foil to reduce the degradation of the ultra-high dose rate. The depth-dose curve beyond the build-up region for the FLASH beam was similar to the conventional 16 MeV electron beam for which the range at 50% the maximum dose (R50) agreed within 0.5 mm. The FLASH beam output remained consistent over a 4-month period with a variation of 2.5%, on average. The FLASH sparing effect was observed in vitro for healthy human pancreatic cells. Furthermore, we observed that the highest PRF beam (180 pulses/s) was more effective at destroying pancreatic cancerous cells while minimizing damage to healthy cells compared to the lowest PRF beam (18 pulses/s). The novel commercial FLASH Research Extension system was dosimetrically characterized for pre-clinical FLASH research, and preliminary in vitro results demonstrated the FLASH effect. Given the prevalence of linear accelerators, this new commercial system has the potential to greatly increase the access to FLASH research.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call