The initial installation of a condition monitoring system (CMS) on a utility scale wind turbine produced a number of unexpected results. The CMS was installed on the TechnoCentre éolien Repower MM92. The installation allowed testing of a MEMS (microelecctromechanical system) based sensor technology and allowed and in-depth analysis of vibration data and revolutions per minute (RPM) data. A large 3/revolution effect, due to tower shadow and wind shear, required the development of an enhanced time synchronous average algorithm. The ability to easily measured changes in main rotor RPM, as a result of tower shadow and wind shear phenomenology, may also facilitate the detection of icing or blade pitch error.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.