Abstract
The objective of this study is to evaluate the inhibitory effect of inorganic and organic coagulant on acidogenic fermentation in municipal wastewater treatment plant. It was found that the conversion from organic matter to Volatile Fatty Acid (VFA) decreased more than 10% when the dosages of coagulant exceeded 46 mg-Al/L and 120 mg-Fe/L. Inhibitory effect by Al on acidogenic fermentation was greater than that by Fe. When the dosage of organic polymer was over 102 mg/L, the VFA conversion fell to below 2%. Ultrasonic treatment could increase the VFA conversion for coagulated sludge for all the coagulants tested (over 12%).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.