Abstract

The short- and long-term effects of chlortetracycline (CTC) on the nitritation- anaerobic ammonium oxidation (anammox) process were evaluated. The half maximal inhibitory concentration of CTC in the batch tests of the nitritation-anammox process was 278.91mg/L at an exposure time of 12hr. The long-term effects of CTC on the process were examined in a continuous-flow nitritation-anammox reactor. Within 14days, the nitrogen removal rate significantly decreased from 0.61 to 0.25kgN/m3/day with 60 mg/L CTC in the influent. The performance suppressed by CTC barely recovered, even after CTC was removed from the influent. Furthermore, the inhibition of CTC also reduced the relative abundance of ammonium oxidizing bacteria (AOB) and anaerobic ammonium oxidizing bacteria (AnAOB) in the reactor, resulting in both a decreased amount of and an imbalance between AOB and AnAOB. When fresh anammox sludge was reseeded into the nitritation-anammox reactor, the nitrogen removal rate recovered to 0.09 ± 0.03 kg N/m3/day.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.