Abstract

Ion migration in Ag-alloy bonding wires was evaluated with water drop tests. The results indicated that water must be present between the wire couple for Ag electrolytic migration to occur. The addition of 1.5 to 4.5% Pd decreased the ion migration rate. Further alloying with about 8% Au enhanced this effect. It seems that the addition of Ni and Pt in Ag-alloy wires does not influence Ag-ion migration. Ag-alloy wires sealed with silicone gel and stressed in air and in distilled water revealed no dendrites after more than 1,000 hr. The ion migration in Ag-alloy bonding wires can be completely inhibited by a suitable encapsulation process with an appropriate molding compound.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.