An increasing amount of evidence suggests that coagulation factors VIII and IX play a role not only in the intrinsic but also in the extrinsic pathway of coagulation. In this context the influence of the Extrinsic Pathway Inhibitor (EPI) on the coagulation time of hemophilia plasma lacking FVIII or FIX has been investigated. The coagulation time was measured in a dilute thromboplastin assay. Addition of recombinant EPI (rEPI) prolonged the coagulation time of normal plasma while the addition of an inhibitory antibody against EPI shortened the coagulation time. At low concentrations of thromboplastin the coagulation time of hemophilia plasma was prolonged and at all dilutions of thromboplastin, addition of anti-EPI IgG normalized the coagulation time of a hemophilia plasma. Analysis of 10 individual donor plasma samples and 8 individual hemophilia samples showed that addition of anti-EPI IgG shortened the coagulation time more in hemophilia plasma than in normal plasma. This illustrates the importance of a powerful extrinsic FVII dependent pathway to achieve hemostasis in the case of FVIII or FIX deficiency (hemophilia A and B).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.