Abstract

From TG result, [Bmim][BF4] has the best inhibition ability of spontaneous coal combustion to delay the initial temperature, maximum temperature, and final temperature of mass loss with oxidation process on lignite and long flame coal. Cation of ionic liquid (IL) is the critical factor of the oxidation reaction on lignite, and [Bmim]+ can destroy the structure of long flame coal. According to FTIR results, ILs can effectively decrease the easily oxidized functional group on lignite, and the removed ability is [Bmim][BF4] > [Emim][BF4] > [Bmim][NO3]. [Emim][BF4] has the best performance of removed ability on long flame coal. ILs as a green inhibitor and new way is applied to prevent fire in coal industries.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.