Abstract
The use of mechanical circulatory support (MCS) devices continues to expand in cases of refractory cardiogenic shock. Bleeding is one of the most common complications associated with MCS, and management can be challenging due to need for systemic anticoagulation. Significant hemoptysis can be a devastating complication. We describe a case of a patient supported by a right ventricular assist device with an oxygenator and a left ventricular assist device who developed pulmonary hemorrhage that was successfully treated with nebulized tranexamic acid (TXA). Following a 5-day treatment course, bleeding resolved, no adverse side effects were noted, and systemic anticoagulation was resumed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.