Abstract

In conducting two-dimensional laminar and turbulence experiments, use of a vertical flowing soap film is often a good choice. However, one of the most frequently encountered and yet highly nontrivial problems is to measure the thickness of the film precisely. We propose a solution to this problem based on the strong absorbtion of infrared light by the water molecules in the film. At λ≃3 μm, a thin sheet of water is essentially opaque. The extinction length of 0.9 μm serves as a precise ruler for gauging the film thickness. Although only the time-averaged, single-point measurements are presented, the technique is general and can be used for multipoint measurements to investigate turbulent driven spatiotemporal fluctuations of the film thickness.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.