Abstract
Infrared (10.6-μm) dynamic holograms are obtained on a recording medium consisting of a thin oil film on a glass substrate. Reconstruction with visible light (0.63 μm) permits copying the initial hologram on a photographic plate. Any subsequent displacement of the object modifies the corresponding reconstructed wave at the recording medium, thereby creating a characteristic visible interferogram. Analysis of the double image in copy holograms together with fringe localization and visibility did not show stringent setup conditions. Experimental results are well related to various objects and displacements while the long wavelength (≃ 10 μm) used offers the advantage of large displacements or wavefronts deformation measurability and considerably decreases the setup sensitivity to vibrations.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.