Abstract
The Canadian Light Source (CLS) is constructing two beamlines for Infrared Spectroscopy using synchrotron radiation (IRSR). One will supply mid-Infrared (2–25 μ) light to a Fourier Transform Infrared (FTIR) spectrometer and microscope for biological applications. The second will have a high resolution FTIR spectrometer for gas-phase and surface spectroscopy in the far-Infrared (beyond 25 μ). The Infrared beamlines will use dipole bending magnet radiation from a special bend magnet port design which provides a 50 mrad square acceptance. Issues with the first mirror and photon mask design, as well as the beamline layout and features are discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.