Abstract

The slight but cumulative influence of impurity gases in air poses a great threat to the long-term stability of room-temperature gas sensors. Room-temperature hydrogen-sensitive Pt–SnO2 composite nanoceramics of 5 wt% Pt were prepared through pressing and sintering. The response of a sample was over 10,000 after being exposed to 500 ppm H2S–20% O2–N2 at room temperature, and the room-temperature hydrogen sensing capacity was seriously degraded even for samples that had aged dozens of days since H2S exposure. Mild heat treatments such as 160 °C for 10 min were found able to fully activate those H2S-exposed samples. As the peak of S 2p electron was clearly detected in H2S-exposed samples, it was proposed that for room-temperature hydrogen-sensitive Pt–SnO2 composite nanoceramics, H2S exposure induced degradation results from the poisoning of Pt by H2S deposited on it, which can be removed through a mild heat treatment. Periodic mild heat treatment should be a convenient and effective measure for room-temperature metal oxide gas sensors to achieve long-term stability through preventing the accumulation of impurity gases in air deposited on them.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.