Abstract
The purpose of this study consisted in examining the effects of fit and fill ratio of the Metha prosthesis (BBraun, Aesculap, Tuttlingen, Germany) on radiological and clinical outcomes at a follow-up of 1 year. 40 patients were included. Fit and fill ratio measurements, radiological and clinical examinations were performed preoperatively and postoperatively. Correlations were established between fit and fill ratio, and potential factors like sex, age, body mass index, Harris Hip Score and changes of radiological signs. The whole cohort (100%) had a tight fit and fill ratio (>0.8) at the proximal level and at each follow-up. "Champagne-flute" configuration provoked high distal tight-fit and fill ratio. Poor distal fit and fill ratio compared to the proximal and the mid-stem level was measurable at each follow-up (p < 0.05). Correlations between fit and fill ratio and preoperative femur configurations were detectable. Implanting the Metha prosthesis induces tight fit and fill ratio at the proximal and coated sections. Preoperative femur configuration should be considered to achieve best fit and fill situation and therefore excellent primary stability. In most cases "normal" and "stove-pipe" configurations provide good proximal fit and fill. Since "champagne-flute" configuration induces undesirable tight distal fit and fill ratio the size of the Metha (®) stem should be adequately increased to achieve a more proximal load transmission.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.