Abstract

Objective To compare the efficacy and visual quality of biocular cataract surgery combined with TECNIS Symfony intraocular lens(IOL) implantation in the correction of presbyopia with three different methods of reserved diopters. Methods A prospective cohort design was adopted.From October in 2016 to December in 2018, 120 patients 240 eyes with binocular cataract surgery implanted TECNIS Symfony IOL were divided into regular group, micro-near-vision group and micro-monovision group according to different reserved diopters, 40 patients 80 eyes in each group.The binocular IOL reserved diopter is + 0.10--0.20 D in regular group.The binocular IOL reserved diopter is -0.20--0.50 D in micro-near-vision group, meanwhile, the dominant eye reserved diopter is + 0.10--0.20 D, and the non-dominant eye reserved the myopia of -0.50--0.75 D in micro-monovision group.Defocus curves of single eye and binocular were measured and full distance visual acuity were analyzed 3 months after surgery.MTF values were detected by iTrace and compared between different groups.Visual function questionnaire of multifocal intraocular lenes (MIOLs)were analyzed and spectacle independence rate of presbyopia correction and disturbing photic phenomena were compared 3 months after surgery.This study protocol was approved by the ethics committee of Chongqing Aier Mega Eye Hospital, and this study followed the Declaration of Helsinki. Results Compared with regular group, the whole defocus curve of micro-near-vision group actually shifted to the right by 0.35 D, with almost no change in shape.The shape of the binocular defocus curve of micro-monovision group changed significantly compared with that of regular group, that is the wave peak became significantly wider, and the downward trend was more gentle.Spectacle independence rate of the three groups were all 100.00%, spectacle independence rate of intermediate distance in Micro-monovision group was 100.00%, which was higher than that of regular group(80.00%) and micro-near-vision group(90.00%), and the differences were statistically significant (χ2=37.04; P 0.05). Conclusions Different reserved diopter design during cataract extraction combined with TECNIS Symfony IOL implantation suits different patients.Among the three different reserved diopters methods, the effect of micro-monovision method can obtain the highest spectacle independence rate, and provide satisfactory binocular far to near full-distance visual acuity. Key words: Cataract; TECNIS Symfony intraocular lens; Micro-monovision; Presbyopia correction

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.