The mechanics principle of setting strengthened storey to control the horizontal displacement in super high-rise structure was analyzed, several super high-rise frame tube structure models were established and the maximum peak displacement as well as storey displacement of the structure under the horizontal earthquake load were analyzed via the finite element program; Utilizing controlling structural horizontal displacement as a judge objective, the appropriate setting number of strengthened storey and optimization location were obtained; eventually, the methods on improving the lateral stiffness via setting beam type strengthened storey in super high-rise frame tube structure were put forward. The obtained conclusions are capable to be a reference for designers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.