Abstract

This article presents the effects of air exchange rate (ACH) and air exchange effectiveness (AEE) on thermal comfort level of a naturally ventilated office room. The study was conducted in an office at UPM, Malaysia. Influence of ACH and AEE on thermal comfort has not been investigated and is, therefore, not well understood. The main objective of this research is to investigate and assess these influences through the variable windows-door opening arrangements. To determine the windows-door opening performance in terms of ventilation air flow rate, 14 opening configurations have been considered. Thermal comfort variables were measured at the same time when ACH and AEE were evaluated. Through these data, the thermal comfort Fanger's indices (Predicted Mean Vote (PMV) and Predicted Percentage Dissatisfied (PPD)), ACH and AEE were calculated. These results showed that for a naturally ventilated office room three linear regression equations of PMV versus ACH and three linear regression equations of PMV versus AEE can be derived.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.