Abstract

Photon and electron specific absorbed fractions (SAFs) and S-values have been evaluated using mouse voxel phantoms. In voxel phantoms, it is important to choose the voxel size carefully since it affects the accuracy of results. In this study, two mouse voxel phantoms were constructed, with cubic voxels, one with 0.1-mm sides and the other with 0.4-mm sides. The sources were considered to be distributed uniformly in the main organs and the radiation transport was simulated using the Monte Carlo code EGS4. It was found that the effect of voxel size on SAFs for self-irradiation was not high (<10 %) for electrons and photons. However, it was appreciable for cross-irradiation especially for electrons. The effect of voxel size was investigated on S-values for some beta emitters such as (131)I, (153)Sm, (188)Re and (90)Y.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.