Abstract

This project investigated the lighting levels required for crosswalk illumination. The current European methods for lighting suggest a crosswalk lighting level of 40 vertical lux for ensured safety. Two major questions were studied: the required vertical illuminance level for adequate pedestrian visibility and the selection of an object that could act as a surrogate for the pedestrian. The vertical illuminance was determined from an experiment that measured the visibility of pedestrians at lighting levels of 5, 20, 40, and 60 vertical lux. During the experiment, a crosswalk scene was presented to the participants and the time taken for identification of an object was measured. In addition to the lighting level, the conditions used in the experiment were lamp type (metal halide versus high-pressure sodium), the presence of glare, the use of overhead lighting, and the type of pedestrian clothing (white, black, and denim). The study found that a lighting design level of 20 vertical lux is likely adequate for...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.