Abstract

ABSTRACTThis paper describes research that evaluated the influence of vacuum pressure, pH, and potential gradient on the vacuum electro-osmosis dewatering (VEOD) of drinking water treatment sludge (DWTS). In the first phase of the VEOD process, a vacuum pressure of −0.05 MPa was applied alone to DWTS for 30 min, removing almost all free water and part of pore water. In phase two, electro-osmosis was applied in combination with intermittent vacuum filtration, further reducing pore water and surface adhesion water in DWTS. However, statistical analysis indicated that the optimum dewatering parameter values were vacuum pressure at −0.06 MPa, pH at 6.2, and potential gradient at 2.5 V/cm, which resulted in a relevant energy consumption of 0.35 kW.h/kg removed water.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.