Abstract

The nature of arrested cracks in run-out fatigue tests of a type 316L austenitic stainless steel with electropolished surfaces has been investigated. The fatigue limit was determined in rotating-bending by means of the staircase method to be 302 ± 5 MPa. Arrested crack nuclei were shown to arrest at coherent deformation twins, developed by fatigue.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.