Abstract

The influence of storage conditions on the total and free concentration of valproic acid (VPA) was studied in six normal male subjects who ingested 750 mg of VPA (3 X 250 mg Depakene capsules; Abbott Laboratories). Blood samples were collected in various types of Vacutainer tubes (red top, no additives; green top, sodium heparin; blue top, sodium citrate; and purple top, EDTA) 2 h post administration of VPA. Either these samples were centrifuged immediately or stored for various periods of time at room temperature or refrigerated, or the supernate was frozen prior to analysis. Free VPA samples were obtained utilizing the Amicon ultrafiltration system. All VPA samples were analyzed by gas-liquid chromatography. Total VPA concentrations obtained from plasma collected with sodium citrate were lower (p less than 0.05) than either serum or plasma collected with other anticoagulants. There were no differences (p greater than 0.05) in total or free VPA concentrations between samples collected in serum or in plasma collected with heparin or EDTA. Storing samples for 96 h at room temperature did not alter the total VPA concentrations but was found to increase the free fraction of VPA (p less than 0.05). The refrigeration or freezing of the supernate from the blood samples for 7 days did not alter (p greater than 0.05) the total or the free fraction of VPA. The results of this study demonstrate that total and/or free VPA may be collected from either serum or plasma, provided sodium citrate is not used to collect plasma.(ABSTRACT TRUNCATED AT 250 WORDS)

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call