Abstract

Although there are many studies on catheter-related infection, there are scarce data about the influence of tracheostomy in the incidence of central venous catheter-related bacteremia (CRB). In this cohort study, we found a higher incidence of CRB in patients with tracheostomy than without (11.25 vs. 1.43 per 1,000 catheter-days; odds ratio [OR] = 7.99; 95% confidence interval [CI] = 4.38-infinite; P < 0.001). Besides, we found a higher incidence of CRB in patients with tracheostomy using the jugular access compared to subclavian access (21.64 vs. 5.11 per 1,000 catheter-days; OR = 4.23; 95% CI = 1.44-infinite; P = 0.0097).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.