Abstract

When ventilating a nonintubated patient in cardiac arrest, the European Resuscitation Council has recently recommended a decrease in the tidal volume from 0.8 to 1.2 L to 0.5 L, partly in an effort to decrease peak flow rate, and therefore, to minimize stomach inflation. The purpose of the present study was to examine the validity of the European Resuscitation Council's recommendation in terms of gas distribution between lungs and stomach in a bench model that simulates ventilation of a nonintubated patient with a self-inflatable bag representing tidal volumes of 0.5 and 0.75 L. A bench model of a patient with a nonintubated airway was used consisting of face mask, manikin head, training lung (lung compliance, 50 mL/cm H2O; airway resistance, 5 cm H2O/L/sec), adjustable lower esophageal sphincter pressure (LESP) and simulated stomach. University hospital laboratory. Thirty healthcare professionals. Healthcare professionals performed 1-min bag-mask ventilation at each LESP level of 5, 10, and 15 cm H2O at a rate of 12 breaths/min, using an adult and pediatric self-inflating bag, respectively. Volunteers were blinded to the LESP, which was randomly varied. Both types of self-inflating bags induced stomach inflation, with higher stomach and lower lung tidal volumes when the LESP was decreased. Lung tidal volume with the pediatric bag was significantly (p < .05) lower at all LESP levels when compared with the adult bag, and ranged between 240 mL at an LESP of 15 cm H2O and 120 mL at an LESP of 5 cm H2O. Stomach tidal volume with the adult bag ranged between 250 mL at an LESP of 15 cm H2O and increased to 550 mL at an LESP of 5 cm H2O. Stomach tidal volume with the pediatric bag was significantly lower (p < .05) at all LESP levels when compared with the adult bag and ranged between 70 mL at an LESP of 15 cm H2O and 300 mL at an LESP of 5 cm H2O. Our data support the recommendation of the European Resuscitation Council to decrease tidal volumes to 0.5 L when ventilating a cardiac arrest victim with an unprotected airway. A small tidal volume may be a better trade-off in the basic life support phase, as this may provide reasonable ventilation while avoiding massive stomach inflation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.