AbstractThis article presents the results of tests on the compressive load capacity of AAC walls with a window opening with a clear span of 1550 mm. Different walls were tested in terms of confinement, concrete and the type of lintel. Standard lintels made of ordinary concrete and prefabricated AAC lintels were built in. Models of walls with additional cores placed along the vertical edges of window openings, in which lintel reinforcement was anchored, were also tested. During the study, apart from the load on the walls and deflection of the lintels, the morphology of cracking of the wall models around the lintel was also analyzed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.