Abstract

Owing to the different pH values of water resources in different places, it is not practical to design hydraulic–mechanical magneto-hydraulic sealing devices under clean water conditions. This study used a Venturi structure to analyze the relationship between the solution pH and cavitation. A high-speed camera and turbine flowmeter were used to record the primary cavitation flow rate, shedding period of the cavitation cloud, and flow direction length of the cavitation cloud of solutions with different pH values. The results showed that acidic and alkaline solutions can inhibit the occurrence of primary cavitation. Compared with clean water, acidic and alkaline solutions have longer cavitation cloud flow length, shortened cavitation cycle, and higher degree of cavitation. In detail, the degree of cavitation in the acidic solution is stronger than that in the alkaline solution. Therefore, the amplitude of the pressure pulsation in an acidic solution should be taken as the reference when designing a hydro-mechanical magneto-hydraulic sealing device.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.