Abstract

The gas permeability of polymer modified mortar coating add steel fiber concrete compound structure was studied by thickness-wall cylinder structure experiment. The coatings were characterized by scanning electron microscope,energy-dispersive X-ray spectroscopy.the gas permeability of steel fiber concrete is 6.85×10-15 m2. applying the coating can reach 10-17 m2. The intrinsic gas permeability of polymer modified cement based materials is 1.36×10-17 m2 using regression calculate analysis method .Coating thickness is constant, raw materials composition and structure is the fundamental factors affecting permeability.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.