Abstract

Previous calculations of the water-to-air stopping power ratio (sw,air) for carbon ion beams did not involve tracking of delta ray electrons, even though previous calculations with protons predict an effect up to 1%. We investigate the effect of the delta ray production threshold in sw,air calculations and propose an empirical expression which takes into account the effect of the delta ray threshold as well as the uncertainty in the mean ionization potentials (I-values) of air and water. The formula is derived from the results of Monte Carlo calculations using the most up-to-date experimental data for I-values and a delta ray production threshold of 10 keV. It allows us to reduce the standard uncertainty in sw,air below 0.8%, instead of the current 2% given in international protocols, which results in a reduction of the overall uncertainty for absolute dosimetry based on air-filled ionization chambers.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.