Abstract

Carbonation of concrete at ambient CO2 concentration is a slow process. This makes the testing of the resistance of concrete against carbonation often too slow to be applicable for service life assessments of new structures. Raising the CO2-concentration will accelerate the test but the validity of an increase CO2-level is debated. If not valid, the service life can be seriously underestimated. In this paper, the effects of accelerating on the carbonation process are discussed.It is shown that a change in CO2 concentration will not change the carbonation process. Since carbonation occurs instantly, a zero CO2 concentration at the carbonation front is maintained. Moreover, it has been concluded that all hydrated and unhydrated cement ultimately carbonates. This implies that the amount of material that can carbonate can be determined on the basis of the amount of calcium in the unreacted cement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.