Abstract

To evaluate the influence of flap tension on the tearing characteristics of mucosal tissue samples in relation to various suture and needle characteristics. Lining and masticatory mucosal tissue samples obtained from pig jaws were prepared for in vitro testing. Tension tearing diagrams of 60 experiments were traced for 3-0, 5-0 and 7-0 sutures with applied forces up to 20 N. In the second part, the same experiments were repeated with 100 diagrams to test the influence of needle characteristics with 5-0 and 6-0 sutures using only gingival tissue samples. 3-0 sutures mainly lead to tissue breakage at an average of 13.4 N. In contrast, 7-0 sutures only resulted in breakage of the thread at a mean applied force of 3.7 N. With 5-0 sutures, both events occurred at random at a mean force of 14.6 N. Irrespective of the needle characteristics, the mean breaking force for gingival samples with 5-0 and 6-0 sutures was approximately 10 N. Tissue trauma may be reduced by choosing finer suture diameters, because thinner (6-0, 7-0) sutures lead to thread breakage rather than tissue breakage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.