Abstract
Experimental investigations for magnetohydrodynamic flows in rectangular ducts are performed using GaInSn as model fluid. Measurements of electric potential on channel walls and inside the flow show reproducible discrepancies compared to analytical results. These discrepancies can be ascribed to the formation of oxide layers causing a contact resistance between the electrically conducting duct walls and the liquid metal. An exact analytical solution for pressure drop, velocity and potential distributions has been derived taking into account the presence of a contact resistance. Analytical results for velocity and potential profiles and for pressure drop are discussed for different values of contact resistance and strength of the applied magnetic field. A comparison of measured potential with data from the analytical solution allows estimating the order of magnitude of the contact resistance in the present experiments.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.