Abstract

Silicon coatings were prepared by vacuum plasma spraying (VPS) and air plasma spraying (APS) technologies. The samples were hydrothermally treated and then incubated in simulated body fluid (SBF) to evaluate their bioactivity and silicon wafer was used as control sample at the same time. The SBF test showed that a Ca-P layer was formed on the surface of silicon wafer and VPS-Si coating after immersion in SBF for certain time, indicating their improved bioactivity. Whereas no Ca-P layer was found on the surface of APS-Si coating. The results of X-ray photoelectron spectroscopy showed that the Si/O atomic ratio and chemical depth profiles of the silicon oxide films on the surface of silicon wafer, VPS-Si and APS-Si coatings were different. The results indicated that the bioactivity difference of silicon-based material resulted from the different composition of their surface. Hydrothermal treatment maybe a favorable method to improve the bioactivity of silicon-based material having silicon oxide of non-stoichiometric Si/O atomic ratio.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call