Abstract
In a study by Law and colleagues recently published in Neuroimage, the authors reported that wearing a surgical mask during an fMRI scan leads to a statistically significant subject-specific change (30%) in the baseline BOLD level in gray matter, although the response to a sensory-motor task was unaffected. An average increase in end-tidal CO2 of 7.4% was found when wearing a mask, despite little support in the literature for major effects of mask wearing on blood gas levels. We comment on these findings, point out a several relevant limitations of the study design and provide alternative interpretations of these data.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.