Abstract

In this paper, the stator end-winding leakage inductance is calculated using a new novel numerical method based on magnetic vector potential, which is highly accurate and comparatively simple. And with this method, the influence of stator end-winding structure on end-winding leakage inductances is discussed. To acquire the end leakage inductances between coils, the flux is calculated by a line integral of vector-potential along the end-winding. Then the phase end leakage inductances can be acquired with the assistance of the incidence matrix. The calculation is illustrated by a 3-phase prototype induction machine, and the influence of the stator end-winding structure on end-winding leakage inductances is discussed according to the calculation results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.