Abstract

AbstractAn experimental statistical design study on the plasma spraying of alumina powder has been carried out. Coating experiments were conducted, using a Taguchi full factorial L 16 design parametric approach, to study the effect of four key plasma processing variables on the coating quality, namely, primary gas flow rate, arc current, powder feed rate, and spray distance. Optical microscopy, scanning electron microscopy, XRD, image analysis, and hardness testing were used for characterisation. The resulting as sprayed coating characteristics were quantified with respect to roughness, microhardness, porosity, and microstructure. Through statistical calculation (analysis of variance), the parameters that have significant influence on the structure and properties of the coatings were identified and their relative importance and contribution ratios to overall variance were studied. The Taguchi evaluation employed in the present investigation showed that an improvement in the coating properties could be ach...

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call