Abstract
Shielding gas nozzle diameter variation and its impact on the anodic power distribution of low-current tungsten inert gas arcs were investigated, while maintaining either shielding gas flow rate or flow velocity constant. In addition, the effects of anode surface condition and flow behaviour type (laminar or turbulent) caused by the shielding gas nozzle applied were studied. It was found that arcs of 50 amperes (A) welding current were highly unstable deploying the conditions used, while increasing the arc electrical current to 100 A led to improved arc stability. As found in previous investigations, non-Gaussian distribution profiles occurred at 50 A, even with improved shielding. The power density maxima were found shifted away from the arc axis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.