Abstract
ABSTRACTThe influence of can size, type of food (conductive or convective), retort temperatures, initial temperature of food and target sterilizing value on steam consumption was studied. A 25 factorial design of experiments was used. Steam consumption was measured by using steam flow meters. A mass average sterilizing value was computed for each process by using experimentally determined heat penetration parameters. Steam consumption was significantly high for processing larger cans compared to smaller cans both containing equal quantities of conduction heating food simulant. The can size had no significant influence on steam consumptions with the convection heating food simulant. Steam consumption and mass average sterilizing values were reduced significantly by employing a high retort temperature to obtain a high target Fp value. With a low target Fp value, the type of food simulant did not affect significantly mass average sterilizing value.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.