Abstract

Purpose: To analyze changes of functional parame¬ters and aberrations before fitting and after using rigid gas-permeable scleral lenses (RGPSCL) in patients with irregular cornea. Material and methods. 21 patients (29 eyes) with irregular astigmatism of various etiology were enrolled in this study. The patients could not achieve good visual aсuity in glasses, standard soft or rigid corneal contact lenses. Complex ophthalmologic examination was per¬formed: autorefractometry, visometry, biomicroscopy, computer corneal topography, aberrometry on “OPD-Scan II” (“Nidek”, Japan) before fitting scleral lenses and during the period of their wearing. Results and discussion. The results demonstrat¬ed significant visual acuity improvement after RGP¬SCL fitting in all observed patients. UCVA amounted to 0.1±0.18, BCVA in glasses amounted to 0.4±0.26, BCVA in RGPSCL amounted to 0.7±0.1. An increase of best-corrected visual acuity in RGPSCL was statistically significant in patients after keratoplasty, after intra-stromal corneal ring segments (ICRS) implantation, af¬ter refractive laser surgery (RLS) and in cases of mixed astigmatism. We have found that the correction of ker¬atoconus with the use of RGPSCL resulted in a decrease of the root mean square value (RMS), measured in the 3 mm and 5 mm zones by 2.5 times and 4 times, re¬spectively. In patients wearing RGPSCL after kerato¬plasty, statistically significant decrease in RMS was observed in the 3 mm zone (by 3.85 times) and in the 5 mm zone (by 2.99 times). In patients wearing RGPSCL after implantation of intrastromal corneal ring segment (ICRS), RMS in the 3 mm zone decreased by 1.5 times. In patients wearing RGPSCL after refractive laser surgery (RLS) RMS was 2.5 times lower in the 3 mm zone and 2.8 times lower in the 5 mm zone. In case of mixed astigmatism correction with RGPSCL, RMS increased by 1.6 times in the 3 mm zone and practically did not change in the 5 mm zone. Conclusion. The results obtained demonstrated significant visual acuity improvement in all observed patients. The sub-lens-space filled with tear forms a unified “cornea-tear-scleral contact lens” optic system that corrects unevenness of cornea, decreases amount of high-order aberrations (HOA) and provides a clear stable vision.

Highlights

  • Тихонова О.И., врач-офтальмолог кабинета контактной коррекции зрения1; Паштаев Н.П., доктор медицинских наук, профессор, директор1, заведующий кафедрой офтальмологии2, заведующий кафедрой офтальмологии и отоларингологии3; Поздеева Н.А., доктор медицинских наук, врач-офтальмолог, заместитель директора по научной работе1,2; Мягков А.В., доктор медицинских наук, профессор, директор4; Бодрова С.Г., кандидат медицинских наук, врач-офтальмолог, заведующая отделом контактной коррекции зрения1; Ситка М.М., кандидат медицинских наук, врач-офтальмолог кабинета контактной коррекции зрения1; Волкова Л.Н., врач-офтальмолог кабинета контактной коррекции зрения1

  • The results demonstrated significant visual acuity improvement after rigid gas-permeable scleral lenses (RGPSCL) fitting in all observed patients

  • An increase of best-corrected visual acuity in RGPSCL was statistically significant in patients after keratoplasty, after intrastromal corneal ring segments (ICRS) implantation, after refractive laser surgery (RLS) and in cases of mixed astigmatism

Read more

Summary

ОРИГИНАЛЬНЫЕ СТАТЬИ

The EYE GLAZ. 2019; V. 21, No 2: P. 32-39. Тихонова О.И., врач-офтальмолог кабинета контактной коррекции зрения; Паштаев Н.П., доктор медицинских наук, профессор, директор, заведующий кафедрой офтальмологии, заведующий кафедрой офтальмологии и отоларингологии; Поздеева Н.А., доктор медицинских наук, врач-офтальмолог, заместитель директора по научной работе; Мягков А.В., доктор медицинских наук, профессор, директор; Бодрова С.Г., кандидат медицинских наук, врач-офтальмолог, заведующая отделом контактной коррекции зрения; Ситка М.М., кандидат медицинских наук, врач-офтальмолог кабинета контактной коррекции зрения; Волкова Л.Н., врач-офтальмолог кабинета контактной коррекции зрения. Влияние склеральных линз на функциональные показатели и аберрации у пациентов с иррегулярной роговицей. Проанализировать изменения функциональных показателей и аберраций до подбора и после коррекции жесткими газопроницаемыми склеральными линзами (ЖГСКЛ) у пациентов с иррегулярной роговицей. Результаты продемонстрировали значительное улучшение остроты зрения после подбора ЖГСКЛ у всех обследованных пациентов. Максимальная корригированная острота зрения в ЖГСКЛ статистически достоверно увеличилась у пациентов после кератопластики, после имплантации интрастромальных роговичных сегментов (ИРС), после рефракционных лазерных операций (РЛО) и при смешанном астигматизме. При ношении ЖГСКЛ после кератопластики наблюдали статистически достоверное уменьшение RMS в 3-мм зоне в 3,85 раза, в 5-мм – в 2,99 раза. У пациентов в ЖГСКЛ после имплантации ИРС RMS в 3-мм зоне уменьшилась в 1,5 раза. В ЖГСКЛ у пациентов после РЛО отмечали снижение RMS в 3-мм зоне в 2,5 раза, в 5-мм – в 2,8 раза.

Острота зрения и аберрации в склеральных линзах
Material and methods
Results and discussion
Conclusion
Материал и методы
Результаты и обсуждение
VA in RGPSCL