Abstract
In this paper the measurement results of a series of standstill frequency response tests, performed at different magnetization levels, are discussed. For each data set an individual model is estimated, which allows the variation of the different parameters to be seen as a function of the saturation. Further, an estimator is presented which uses the different data sets to estimate one global model, including the field to armature turns ratio. Finally the expected error level of a more traditional saturated synchronous machine model is studied.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.