Abstract
The increasing popularity of ground-coupled heat pumps has resulted in almost 20% of all Swedish family houses being heated this way. To avoid undesirable interactions between neighboring boreholes and disturbance of the ground temperature, the general rule and recommendation of Swedish authorities is that the distance between two neighboring boreholes must be ≥20m. However, according to previous studies, relatively low groundwater flow rates may significantly reduce the borehole excess temperature compared to the case of pure heat conduction.In this work the Influence Length is defined and its relations with flow rate, real thermal conductivity of the ground and effective thermal conductivity obtained by thermal response analysis are investigated. The aim of this study was to find a way to use the thermal response test as a means to determine the groundwater flow influence in order to reduce the borehole spacing perpendicular to groundwater flow direction.The results confirm that very low groundwater flow rates are enough to significantly reduce the Influence Length, hence this is a crucial parameter which should be considered. Moreover, a first estimation, even before the thermal response test analysis, of the Influence Length is possible if the knowledge of hydrogeological conditions of the site allows good predictions about real thermal conductivity of the ground and flow rate.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.