Abstract

PurposeProximal humerus fractures (PHFs) are common. With the development of locking plates, open reduction and internal fixation (ORIF) of the proximal humerus can provide excellent clinical outcomes. The quality of fracture reduction is crucial in the locking plate fixation of proximal humeral fractures. The purpose of this study was to determine the impact of 3-dimensional (3D) printing technology and computer virtual technology assisted preoperative simulation on the reduction quality and clinical outcomes of 3-part and 4-part proximal humeral fractures.MethodA retrospective comparative analysis of 3-part and 4-part PHFs undergoing open reduction internal fixation was performed. Patients were divided into 2 groups according to whether computer virtual technology and 3D printed technology were used for preoperative simulation: the simulation group and the conventional group. Operative time, intraoperative bleeding, hospital stay, quality of fracture reduction, Constant scores, American Society for Shoulder and Elbow Surgery (ASES) scores, shoulder range of motion, complications, and revision surgeries were assessed.ResultsThis study included 67 patients (58.3%) in the conventional group and 48 patients (41.7%) in the simulation group. The patient demographics and fracture characteristics were comparable in these groups. Compared with the conventional group, the simulation group had shorter operation time and less intraoperative bleeding (P < 0.001, both). Immediate postoperative assessment of fracture reduction showed a higher incidence of greater tuberosity cranialization of < 5 mm, neck-shaft angle of 120° to 150°, and head shaft displacement of < 5 mm in the simulation group. The incidence of good reduction was 2.6 times higher in the simulation group than in the conventional group (95% CI, 1.2–5.8). At the final follow-up, the chance of forward flexion > 120° (OR 5.8, 95% CI 1.8–18.0) and mean constant score of > 65 (OR 3.4, 95% CI 1.5–7.4) was higher in the simulation group than the conventional group, as well as a lower incidence of complications in the simulation group was obtained (OR 0.2, 95% CI 0.1–0.6).ConclusionsThis study identified that preoperative simulation assisted by computer virtual technology and 3D printed technology can improve reduction quality and clinical outcomes in treatment of 3-part and 4-part PHFs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call